Distance Settings
* Default settings
Switch 1 Switch 2 Switch 3
Distance
EU, CN Models US, UK Models
0 0 0 2 m (6.6 ft) 3 m (9.8 ft)
0 0 1 3 m (9.8 ft) 4 m (13.1 ft)
0 1 0 4 m (13.1 ft) 5 m (16.4 ft)
0 1 1 6 m (19.7 ft) 6 m (19.7 ft)
1* 0* 0* 8 m (26.2 ft) 8 m (26.2 ft)
1 0 1 10 m (32.8 ft) 10 m (32.8 ft)
1 1 0 12 m (39.4 ft) 12 m (39.4 ft)
1 1 1 15 m (49.2 ft) 15 m (49.2 ft)
NOTE: Highest sensitivity is achieved only if sensing distance is 8 m (26.2 ft) or less
Sensitivity Selection
* Default settings
Switch 4 Switch 5 Switch 6 Sensitivity
0* 0* 0* 8 (Highest)
0 0 1 7
0 1 0 6
0 1 1 5
1 0 0 4
1 0 1 3
1 1 0 2
1 1 1 1 (Lowest)
NOTE: Use the sensitivity selection to ignore unwanted weak reflections within the field of view, and not to
narrow the beam width. Narrow-beam R-GAGE sensor models are available.
Output Configuration
* Default settings
Switch 7 Normally Open/Normally Closed
0* N.O.
1 N.C.
R-GAGE™ QT50RAF Sensor
P/N 135460_web
Rev. E
www.bannerengineering.com - tel: 763-544-3164 3
Komentarze do niniejszej Instrukcji