LIGHT GAUGING
ULTRASONIC
QT50U
S18U
QS18U
T30U/T30UX
M25U
T18U
Q45U
Q45UR
MEASURING
ARRAYS
RADAR
More information online at bannerengineering.com 333
Photoelectrics
Sensors
Fiber Optic
Sensors
Special Purpose
Sensors
Measurement &
Inspection Sensors
Vision
Wireless
Lighting &
Indicators
Safety
Light Screens
Safety
Laser Scanners
Fiber Optic
Safety Systems
Safety Controllers &
Modules
Safety Two-Hand
Control Modules
Safety Interlock
Switches
Emergency Stop &
Stop Control
ACCESSORIES
page
335
U-GAGE
®
Q45U Analog Output, 15-24V dc
Range
Temperature
Compensation Connection *
Output
Type
Response
Time Models
100 mm - 1.4 m Yes
2 m
Selectable
0 to 10V dc
or
4 to 20 mA
Adjustable from
40 to 1280 ms
Q45ULIU64ACR
5-pin Mini QD Q45ULIU64ACRQ
5-pin Euro QD Q45ULIU64ACRQ6
250 mm - 3 m
Yes
2 m
Adjustable from
80 to 2560 ms
Q45ULIU64BCR
5-pin Mini QD Q45ULIU64BCRQ
5-pin Euro QD Q45ULIU64BCRQ6
More
on next
page
U-GAGE
®
Q45U Discrete Output, 12-24V dc
Range
Temperature
Compensation Connection
Output
Type
Response
Time Models
250 mm - 3 m
Yes
2 m
Bipolar
NPN/PNP
Programmable for
40, 80, 320
or 1280 ms
Q45UBB63BC
5-pin Mini QD Q45UBB63BCQ
5-pin Euro QD Q45UBB63BCQ6
(cont’d)
U-GAGE
®
Q45U Specifications
Sensing Range
Short Range: Near limit: 100 mm min. Long Range: Near limit: 250 mm min.
Short Range: Far limit: 1.4 m max. Long Range: Far limit: 3.0 m max.
NOTE: The far limit may be extended on long range units, as far as 3.9 m for good acoustical targets (hard surfaces with
area greater than 100 cm
2
)
Supply Voltage and Current
Discrete: 12 to 24V dc (10% max. ripple); 100 mA (exclusive of load)
Analog: 15 to 24V dc (10% max. ripple); 100 mA (exclusive of load)
Ultrasonic Frequency
Long Range: 128 kHz Short Range: 230 kHz
Supply Protection Circuitry
Protected against reverse polarity and transient voltages.
Output Protection Circuitry
Protected against false pulse on power-up and continuous overload or short-circuit of outputs.
Output Configuration
Discrete: Bipolar: One current sourcing (PNP) and one current sinking (NPN) open-collector transistor.
Analog: One voltage sourcing and one current sourcing; one or the other output is enabled by internal programming switch #2.
Output Ratings
Discrete: 150 mA max. (each)
OFF-state leakage current: less than 25 µA at 24V dc
ON-state saturation voltage: less than 1.5V at 10 mA; less than 2.0V at 150 mA
Analog: Voltage sourcing: 0 to 10V dc, 10 mA max.
Current sourcing: 4 to 20 mA, 1 to 500 Ω impedance
Connection options: A model with a QD requires a mating cordset (see page 335).
For 9 m cable, add suffix W/30 to the 2 m model number (example, Q45UBB63DA W/30).
The far limit may be extended as far as 3.9 m for good acoustical targetshard surfaces with area greater than 100 cm