E – Coil Tester
DPN 402197 © TSS (International) Ltd Page 3 of 10
E.1 PRE-OPERATION
Prior to using the Coil Tester:
❐ Read the complete 350 Cable Survey System Manual.
❐ Install the 350 System according to the instructions provided in Section 3 Physical
Installation and Section 4 Electrical Installation.
❐ Ensure the coil calibration constants configured on the Surface Display Computer
(SDC) correspond to the values displayed on the brass connector flanges of the
search coils.
E.1.1 Coil Calibration Constants
TSS takes care during manufacture to ensure the coils and pre-amplifiers are
matched. However, there will inevitably be some residual differences between individ-
ual sensing coils.
Each of the sensing coils supplied by TSS has an identification plate that includes a
calibration constant. The 350 Cable Survey System requires this information to com-
pensate for the residual differences between the search coils.
During the coil installation process record the following information:
1. The calibration constants for each of the six search coils.
2. The serial number of each of the six search coils.
3. All search coil positions.
This information can be recorded on the Configuration Log Form in Appendix F.
To access the 350 System Configuration dialog press [SHIFT+F2]
TSS supply the 350 System with port and starboard coil triads assembled and the coil
calibration constants already configured in the Surface Display Computer (SDC), as
shown in Figure E–1 below. However, ensure the values displayed in 350 System
Parameters Configuration screen correspond to the values stamped on the brass
connector flanges of the search coils.