350 Cable Survey System
DPN 402197 © TSS (International) Ltd Page 10 of 14
CAUTION
You might damage the SEP if you attempt to operate it from an incorrect electrical sup-
ply. Pay careful attention to the requirements of the SEP and provide a supply of the
correct rating.
A switched-mode supply inside the SEP generates the conditioned and stabilised DC
supplies required by the sub-sea electronics. The input to the switched mode supply
includes a line fuse accessible inside the SEP.
The SEP is a sealed unit with six ports:
On one end-cap:
Power/comms.
This port accepts the AC electrical supply from the ROV. It also carries the com-
munication signals that pass between the sub-sea installation and the SDC.
Altimeter.
You may connect the TSS or the Datasonics sub-sea altimeter directly to this port.
The port provides DC power to operate these types of altimeter and a signal path
for their RS232 communications.
Aux Output.
You must use this port to connect the 350 SEP to the 440 System if you intend to
use your 350 System in a Dualtrack installation. Refer to Appendix B for a descrip-
tion of the Dualtrack System. If you do not make any electrical connections to the
‘Aux Output’ port you must leave the blanking plug securely attached to it.
Sensor
The 350 System does not use this port. Leave the blanking plug securely attached
to the Sensor port.
On the other end-cap:
There are two electrically identical connection ports for connection to the two coil tri-
ads. You must connect each coil to its correct port on the SEP. Refer to sub-sec-
tion 4.1.4 for instructions to connect the coils.
CAUTION
You might damage the SEP if you leave any port exposed to sea water during deploy-
ment on the ROV, even if you are not using the 350 System.
You must fit the supplied blanking plugs to any port on the SEP that you will not be
using during ROV deployment.
Refer to sub-section 3.2.1 for instructions to install the SEP on the ROV.