350 Cable Survey System
DPN 402197 © TSS (International) Ltd Page 6 of 10
5.3.2 Communication ports
Define the serial communication ports and their communication parameters. The SDC
uses the serial communication ports to communicate with the SEP and with external
devices such as the sub-sea altimeter and a data logger.
During System Configuration the only port that you have to specify is the Communica-
tion to the Sub Sea Electronic Pod (or SEP). Below is outlined a list of the COM Ports
and their default assignments.
The SDC has five serial communication ports that it uses to communicate with exter-
nal and peripheral equipment. The standard assignations for these ports are as fol-
lows. You may change these if necessary.
COM1 is used to pass serial communications between the SEP and the SDC.
DeepView uses a serial port for this purpose even if you set the 350 System to
use current-loop communications. The SDC includes the hardware necessary to
convert between these standards.
Note that the current-loop communications connects through a jumper link from the
current-loop converter card. If you decide to use an alternative serial communications
port for the primary communications circuit, then you must also move the link connec-
tion to the alternative serial port.
COM2 (labelled ‘ALTIMETER’ on the rear connector panel of the SDC) is used to
accept serial data from any compatible altimeter that is not connected directly to
the SEP. The maximum range for RS232 communications is 15 metres. There-
fore, to connect an altimeter to the SDC you must add its signals to an existing
multiplexed data link in the ROV umbilical and then extract them at the surface.
Refer to sub-section 6.2.2.1 for instructions to configure an altimeter and set its
communication parameters.
COM3 (labelled ‘LOG O/P’ on the rear connector panel of the SDC) is used to
connect the SDC to a separate user-supplied data logger. You should use a data
logger to record the survey measurements acquired by the 350 System. Refer to
sub-section 6.2.2.2 for instructions to configure DeepView for data logging and to
set appropriate communication parameters.
COM5 (is not available on the rear connector panel of the SDC) is used by the
SDC to communicate with the video overlay card.
DeepView for Windows allows you to set the communication parameters for each of
the serial ports. Choose settings that are appropriate for the connected equipment –
refer to the technical manuals of the attached equipment if necessary. Note that the
standard communication parameters for COM1, the communication link between the
SDC and the SEP are set to operate at 9600 baud using 8 data bits, two stop bits and
no parity.